ADV-MXM-501
Advanced
Semi-flush bezel for Axis EN panel in small enclosure
345 x 340 mm (HxW)
Not Available For Sale 0.0 EUR
ADV-MXM-503
Advanced
Semi-flush bezel for Axis EN panel in large enclosure
475 x 450 mm (HxW)
Not Available For Sale 0.0 EUR
ADV-MXM-521
Advanced
Semi-flush bezel for Axis EN repeaters
ADV-MX-5010 / 5020
220 x 300 mm (HxW)
Not Available For Sale 0.0 EUR
ADV-MXP-501
Advanced
Battery Temperature Sensor
Not Available For Sale 0.0 EUR
ADV-MXP-502
The loop controller board is designed for use with the Axis EN range of analogue addressable control units
Provides control and connection to detector loops.
ADV-MXP-502 loop controller card is compatible with Apollo, Hochiki or Argus Vega.
ADV- MXP-567 loop controller card is compatible with Nittan protocol
Not Available For Sale 0.0 EUR
ADV-MXP-509
Advanced
Fault Tolerant Ad-Net Network Card
Allows installation of up to 200 nodes
Up to 1.5 km of distance between nodes
Total network 20 Km
Not Available For Sale 0.0 EUR
ADV-MXP-510-BX
Advanced
Interface for plan management with standard network card
Connected to the AD-NET network
1 solo interface por red necesario - Versiones para red estándar y tolerante a fallos
Easily configured through PC-NET-003
Not Available For Sale 0.0 EUR
ADV-MXP-554-BX
Advanced
Network interface for IP connection with standard AD-NET network card built-in
1 only one module gives access to all the control panels of the AD-NET network
Configurable e-mail notification per event
Maximum 2 simultaneous users
Minimum screen resolution 1024 x 768
Compatibility with Axis EN series fire panels, Mx-5000 and Mx-4000
Not Available For Sale 0.0 EUR
ADV-TOUCH-10
Advanced
Touch screen repeater
10" screen
Easy-to-use interface with easily configurable active maps using the Dynamix Tools Map application
Allows to evacuate / silence / resonate / restart / see fires / faults / disables / alarms / inputs / outputs...
1.000 registrations of general events and 500 fires
Surface and recessed accessories
Resolution 1280x800 (720p)
Standard network card integrated in the equipment for equipment connection
Not Available For Sale 0.0 EUR
ADV-AXIS-TME
Advanced
Wireless amplifier
Up to 15 expanders used with each ADV-AXIS-TMT
Easy installation, externally motorized
Bidirectional communications with all devices
Taurus uses NetworkOptimiser technology, with more than 60 communication channels to avoid interference and channel collisions, regardless of the extent of the fire network or the scale of the building.
Each device features SafeSwitch dual redundant channel technology, so that if one channel fails, the other automatically takes over, ensuring unprecedented levels of reliability and performance.
The key to any successful wireless fire system is design and specification, which is why TauREX software has been developed, featuring an easy-to-use graphical user interface and innovative new features, such as EasyScan and ConfigWizard, to help specify the optimal system for each installation in a simple and intuitive way.
It also offers unprecedented system reliability and performance using SafePath Mesh Expander technology. If any chain expander fails, the transmission path uses an alternative path, ensuring continuity of communication.
Not Available For Sale 0.0 EUR
ADV-AXIS-TMT
Taurus uses NetworkOptimiser technology, with more than 60 communication channels to avoid interference and channel collisions, regardless of the extent of the fire network or the scale of the building.
Each device features SafeSwitch dual redundant channel technology, so that if one channel fails, the other automatically takes over, ensuring unprecedented levels of reliability and performance.
The key to any successful wireless fire system is design and specification, which is why TauREX software has been developed, featuring an easy-to-use graphical user interface and innovative new features, such as EasyScan and ConfigWizard, to help specify the optimal system for each installation in a simple and intuitive way.
It also offers unprecedented system reliability and performance using SafePath Mesh Expander technology. If any chain expander fails, the transmission path uses an alternative path, ensuring continuity of communication.
Advanced
Analog interface module for wireless detectors
Compatible with TAURUS equipment
Each module allows the addition of up to 32 wireless sensors, sirens or modules
Several modules can be placed in the same loop
Recommended frequency in Europe of 868 MHz and according to the EN54-25 standard
Not Available For Sale 0.0 EUR
ADV-ESMX-5010
Advanced
Remote Display Terminal - Built-in keypad with internal repeater siren mute, view, enable/disable and test buttons
Allows you to see all the information of the network
Operating voltage 24V DC - Customizable LCD logo
Standard network card integrated in the equipment for equipment connection
Not Available For Sale 0.0 EUR
ADV-MXP-503
Advanced
Standard Ad-Net Network Card
Allows installation of up to 32 nodes
Up to 1.5 km of distance between nodes
Not Available For Sale 0.0 EUR
ADV-UA-BCW-H37
Advanced
High profile base supplement
Compatible with the base ADV-VB100 and ADV-AXIS-MB (required to operate)
Necessary for the detector installation
Easy mounting mark
Height of 37mm
Not Available For Sale 0.0 EUR
ADV-AXIS-CWS
High-performance conventional wall-mounted siren with EN54-3, certification, designed to integrate with Advanced's alarm and smart hybrid systems via the ADV-AXIS-WSM module
Advanced
Conventional siren
Needs ADV-AXIS-WSM module to connect to analog loop
Equipped with 4 volume adjustment levels and 32 recognized tones that can be configured through the control equipment or locally on the siren
Certified in EN54-3
Two-stage alarm capability
Not Available For Sale 0.0 EUR
ADV-AXIS-CWSV
It is an optical-acoustic alarm device (siren with VAD) - A conventional wall-mounted Visual Alarm Device (VAD) manufactured by Advanced that can be converted to analog using an ADV-AXIS-WSM module for loop connection. It is designed to provide a highly reliable dual evacuation signaling system, combining a powerful audible alarm with a wide-coverage flashing visual signal..
The equipment is certified in accordance with the EN54-3 standard (for the acoustic component) and the EN54-23 standard
Advanced
Siren and conventional flash
Needs ADV-AXIS-WSM module to connect to analog loop
Equipped with 4 volume adjustment levels and 32 recognized tones that can be configured through the control equipment or locally on the siren
Certified in EN54-3 and EN54-23
Two-stage alarm capability
Not Available For Sale 0.0 EUR
ADV-MXP-567
The advanced loop controller card allows the expansion of an additional loop for an MxPro 5 panel as long as the panel has the required capacity. nittan protocol compatible.
Advanced Loop Controller Card
Allows communication with Nittan protocol
Not Available For Sale 0.0 EUR
ADV-MXP-568
Advanced's ADV-MXP-568 is not just a simple expansion card; it is the intelligent control core of the 2 Generation, designed specifically for the multi-award-winning line of addressable analog control panels. This electronic board is responsible for providing operational control, critical power supply, and continuous two-way communication with all detectors and peripherals installed in the fire loop.
Its main value proposition lies in its unrivaled multi-protocol architecture. It is specifically optimized to support the advanced Apollo CoreProtocol (Soteria series), while maintaining full operational compatibility with the classic Apollo XP95 and Discovery series, the Hochiki ESP protocol, Argus Vega technology, and the native Axis EN line.
Advanced systems compliant with the EN54-2,, EN54-4, and EN54-13 standards.
Advanced Loop Controller Card
Full compatibility with the Apollo Core protocol.
Supports Hochiki ESP, Argus Vega, and Axis EN.
Official driver for Advanced Gen panels 2.
Backward compatible with previous Gen 1 controllers.
Smart control of up to 240 points.
Not Available For Sale 0.0 EUR
ADV-AXIS-5804-ES
Addressable analog fire protection control panel with 4 high-power loops, physically expandable to a maximum of 8 loops. 2 high-performance loops, part of Advanced's premium Axis EN line, and two other ADV-MXP-568 loops compatible with the Apollo, Hochiki, Argus, and AxisEN protocols. Available in the Advanced Large Enclosure and optimized for the Spanish market with a Spanish-language display and interface, and compliant with RIPCI. It offers the highest level of control and power in a single cabinet within the Axis EN product line, designed for large-scale, mission-critical infrastructure.
Advanced
Central of 4 loops expandable to 8
2 AXIS proprietary protocol loop
2 Argus Vega, Apollo, and Hochiki multiprotocol loops
Up to 240 devices per loop
Ad-Net peer-to-peer network capable of managing up to 2000 zones
Programmable function buttons
8 siren outputs
USB communication ports and RS232
20 LED for programmable zones
Graphical LCD user interface and support for up to 200 default fire zones, enabling full compliance with the EN54 standard.
Compatible with IP module (installed in network, 1 only module for the whole system)
Removable terminals for hot extraction
Quick-extraction main plate. Easy removal of PCB from the housing
Rack mountable
Customizable LCD logo
Multi-language
Certified EN 54-2:1997, EN 54-4:1997 and EN 54-13:2005 Certificate in EN54 Parts 2 and 4 by FM Approvals
Not Available For Sale 0.0 EUR
ADV-AXIS-5101-ES
High-performance 1-loop addressable analog fire protection control panel from Advanced's premium Axis EN series. Designed with a dual-processor architecture and specifically optimized for the Spanish market, featuring a Spanish-language user interface and strict compliance with RIPCI regulations. It offers mission-critical reliability in a compact format without sacrificing the grid-scale power of large power plants.
Advanced
Central of 1 non-extendable loops
AXIS Custom Protocol Loopback
Up to 240 devices per loop
Ad-Net peer-to-peer network capable of managing up to 2000 zones
Programmable function buttons
2 siren outputs
USB communication ports and RS232
20 LED for programmable zones
Graphical LCD user interface and support for up to 200 default fire zones, enabling full compliance with the EN54 standard.
Compatible with IP module (installed in network, 1 only module for the whole system)
Removable terminals for hot extraction
Quick-extraction main plate. Easy removal of PCB from the housing
Rack mountable
Customizable LCD logo
Multi-language
Certified EN 54-2:1997, EN 54-4:1997 and EN 54-13:2005 Certificate in EN54 Parts 2 and 4 by FM Approvals
Not Available For Sale 0.0 EUR